Single Channel Bio-Fragment Analyzer : Qsep100 2.0

Qsep100 2.0 ¹ÙÀÌ¿À ´ÜÆí ºÐ¼®±â´Â ƯÇã¹ÞÀº LEDIF °ËÃâ ±â¼ú°ú ¿ÏÀü ÀÚµ¿È¸¦ °áÇÕÇÏ¿© °íÇØ»óµµ, °í°¨µµ, ³ôÀº ÀçÇö¼ºÀ» Á¦°øÇÏ´Â ¸ð¼¼°ü gel Àü±â¿µµ¿ÀÇ »õ·Î¿î ½Ã´ë¸¦ ¿¾ú½À´Ï´Ù. DNA, RNA, protein fragments µî ´Ù¾çÇÑ ºÐ¼®ÀÌ °¡´ÉÇÏ¿© ¿©·¯ ºÐ¾ßÀÇ ¿¬±¸¸¦ Áö¿øÇÕ´Ï´Ù. ¹Ù·Î »ç¿ëÇÒ ¼ö ÀÖ´Â cartridge¸¦ ÅëÇØ standard PCR tubes ¶Ç´Â 96 well plates¿¡ ´ã±ä samples¸¦ ±â±â¿¡ Á÷Á¢ ³Ö¾î ºÐ¼®ÇÒ ¼ö ÀÖÀ¸¸ç, ÁÖÀÔ, Àü¾Ð, ºÐ¼® Á¶°ÇÀ» À¯¿¬ÇÏ°Ô Á¦¾îÇÏ¿© 3ºÐ À̳»¿¡ Áغñ ¹× ÀÛµ¿ÀÌ °¡´ÉÇÕ´Ï´Ù. ´ÜÀÏ sampleºÎÅÍ ÃÖ´ë 96 well(384 well±îÁö È®Àå °¡´É)±îÁö 󸮷®À» Áö¿øÇÏ¿© Çö´ë ½ÇÇè½Ç¿¡ Ź¿ùÇÑ È®À强°ú È¿À²¼ºÀ» Á¦°øÇÕ´Ï´Ù.
ÀÏȸ¿ë Gel-Cartridge (Gel Áغñ ¾øÀÌ 100~200°³ »ùÇà ó¸® °¡´É)
DNA: S1, S2, S3, N1, N3
RNA: R1, NR1
Protein: P2

Feature
- 1
¾ÈÀüÇÏ°í °£ÆíÇÑ ready-to-use gel capillary column
- 2
īƮ¸®Áö¿¡ RFID°¡ ºÎÂøµÇ¾î ÀÖ¾î, ±â±â¿¡ »ðÀÔÇϸé ÀÜ¿©»ç¿ëȽ¼ö/À¯È¿±â°£À» È®ÀÎÇÒ ¼ö ÀÖÀ½
- 3
RNA Quality Number (RQN)À» Á¦°øÇÏ¿© RNA integrity¸¦ È®ÀÎÇÒ ¼ö ÀÖÀ½
- 4
2-7ºÐ ³»¿¡ »ùÇà ºÐ¼®°¡´É
- 5
1 ~ 4bp ±¸ºÐ °¡´ÉÇÑ °í ÇØ»óµµ (High Resolution cartridge)
- 6
Àú·ÅÇÑ running cost (°ª ºñ½Ñ chip, Çü±¤ dye ÇÊ¿ä ¾øÀ½)
- 7
2pg/µlÀÇ ³óµµµµ ºÐ¼® °¡´ÉÇÑ °í°¨µµ
- 8
¿øÇÏ´Â »ùÇø¸À» ¼±ÅÃÇÏ¿© ºÐ¼® °¡´ÉÇÑ Cherry picking System
Specification
| Specification | |
|---|---|
| Detection | Fluorescence |
| Light Source | LED |
| Separated Voltage | 1~15kV |
| Connection | USB |
| Power Source | AC100 ~ 240V, 120W |
| Minimum Power | 30W |
| System Weight | 16.5 kg |
| Dimension | 41*30*43 cm |
| Highlights | |
|---|---|
| System Type | 1 Channel Standard System |
| Automated Sampling | 1~96 samples (384-well Customizable) |
| Disposable Gel-Cartridge (100~200 sample capacity without gel preparation) |
Single Channel Cartridge: ¤ýDNA: S1, S2, S3, N1, N3 ¤ýRNA : R1, NR1 ¤ýProtein: P2 |
| Rapid Analysis | 2~7 mins/ sample (below 1 kb) |
| Resolution | 1~4 bp (below 500 bp) |
| Sensitivity | 5 pg/¥ìL *1pg/ ¥ìL(if dilluted in ddH2O) |
| Minimum Sample Volume | 2¥ìL(Micro Vial, C104250) 10¥ìL(0.1mL Tube) 10¥ìL(0.2mL Tube) |
| Sample Consumption | ¡Â1pL |
| Software: Q-Analyzer | ¤ýRelative qualitative and quantitative analysis Electrophoresis ¤ýGel view image ¤ýCustomer-oriented report |
Cartridge Specification
| Cartridge | Standard (S2) |
High Resolution (S1) |
Kilo Base (S3) |
High Sensitivity (N1) |
High Sensitivity Kilo Base (N3) |
RNA (R1) |
High Sensitivity RNA (NR1) |
|---|---|---|---|---|---|---|---|
| Sample size range | 10-5,000 bp | 10-5,000 bp | 20-60,000 bp | 10-5,000 bp | 20-60,000 bp Detection Range: 20bp~ 165kbp |
20-6,000 nt | 20-6,000 nt |
| L.O.D. | 0.1 ng/¥ìl 2 pg/µL in water |
0.1 ng/¥ìl 2 pg/µL in water |
0.1 ng/¥ìl 2 pg/µL in water |
5 pg/¥ìl 1 pg/µL in water |
20 pg/¥ìl 1 pg/µL in water |
5 ng/¥ìl 1 pg/µL in water |
1 ng/¥ìl 0.2ng/µL in water |
| Resolution | 4-10 bp | 1-4 bp | 10-50 bp | 4-10 bp | 10-50 bp | N/A | N/A |
| Time (per sample) | 2-3min | 3-5min | 9-21min *5mins (below 1kb) |
2-3min | 9~25 min *3 mins (below 1 kb) |
5-8min | 5-8min |
Product Information
C100200 Package (Qsep 100 2.0)
| Cat No. | ǰ¸í | ±Ô°Ý | Á¦Á¶»ç | Á¦Ç°Á¤º¸ |
|---|---|---|---|---|
| C100200 | Qsep100 2.0 DNA Analyzer | 1SETS | BiOptic | - ACE Device with Q-Analyzer Software, including 1-year Warranty. |
| C101010 | Software Key (Basic) | 1Pc | BiOptic | - |
| C104301-00 | Qairbox | 1Pc | BiOptic | -Portable DC Air Pump -ON: 60PSI, OFF: 50PSI -DC 12V |
| C105200 | S1 & S2 Cartridge Kit(2pcs) | 1SETS | BiOptic | - 2 Cartridges & Buffer Solution |
| C109100-500A | 20&1k ALIGNMENT MARKER | 1Tube | BiOptic | - 20bp&1000bp /500ul |
| C109102-500A | 20&5k ALIGNMENT MARKER | 1Tube | BiOptic | - 20bp&5000bp/500ul |
| C109200 | Size Marker (15-622bp) | 1Tube | BiOptic | - pBR322-MspI 500¥ìL |
| C109300 | 50bp 3K DNA Ladder | 1Tube | BiOptic | - 500ul |
| Cartridge | Cat No. | ǰ¸í | ±Ô°Ý | Á¦Á¶»ç | Á¦Ç°Á¤º¸ |
|---|---|---|---|---|---|
| C105102 | S1-High Resolution Cartridge (200 runs/cartridge) |
1pc | BiOptic | - | |
| C105202 | S1-High Resolution Cartridge (200 runs/cartridge) |
2pcs | BiOptic | - | |
| C105802 | S1-High Resolution Cartridge (200 runs/cartridge) |
8pcs | BiOptic | - | |
| C105101 | S2-Standard Cartridge (200 runs/cartridge) |
1pc | BiOptic | - | |
| C105201 | S2-Standard Cartridge (200 runs/cartridge) |
2pcs | BiOptic | - | |
| C105801 | S2-Standard Cartridge (200 runs/cartridge) |
8pcs | BiOptic | - | |
| C105106 | S3-Kilobase Cartridge (200 runs/cartridge) |
1pc | BiOptic | - | |
| C105206 | S3-Kilobase Cartridge (200 runs/cartridge) |
2pcs | BiOptic | - | |
| C105806 | S3-Kilobase Cartridge (200 runs/cartridge) |
8pcs | BiOptic | - | |
| C105105 | N1-High Sensitivity Cartridge (100 runs/cartridge) |
1pc | BiOptic | - | |
| C105105 | N1-High Sensitivity Cartridge (100 runs/cartridge) |
2pcs | BiOptic | - | |
| C105205 | N1-High Sensitivity Cartridge (100 runs/cartridge) |
8pcs | BiOptic | - | |
| C105153 | N3-High Sensitivity Kilobase Cartridge (100 runs/cartridge) |
1pc | BiOptic | - | |
| C105253 | N3-High Sensitivity Kilobase Cartridge (100 runs/cartridge) |
2pcs | BiOptic | - | |
| C105110 | R1-RNA Cartridge (100 runs/cartridge) |
1pc | BiOptic | - | |
| C105210 | R1-RNA Cartridge (100 runs/cartridge) |
2pcs | BiOptic | - | |
| C105810 | R1-RNA Cartridge (100 runs/cartridge) |
8pcs | BiOptic | - | |
| C105111 | NR1-High Sensitivity RNA Cartridge (100 runs/cartridge) |
1pc | BiOptic | - | |
| C105211 | NR1-High Sensitivity RNA Cartridge (100 runs/cartridge) |
2pcs | BiOptic | - | |
| C105801 | NR1-High Sensitivity RNA Cartridge (100 runs/cartridge) |
8pcs | BiOptic | - |